Guided vs escaping fractions

Isotropic-source geometry; a closed-form fraction you can trust.

Lesson 2 of 5 · ~7 min read

For an isotropic source inside a planar slab of index n1, the fraction of rays that hit the top (or bottom) face inside the escape cone is

fescape = (1 − cos θc) / 2
(4.2.1)

per face, so the fraction trapped by TIR at that face is cos θc (the complementary band of angles). For a slab bounded above and below by the same lower-index medium, light trapped at the top can still escape at the bottom; the full guided fraction depends on geometry (edge-fed sheet vs. isotropic point source).

Why the formula is simple

An isotropic source emits uniformly over 4π steradians. The escape cone is a spherical cap of half-angle θc; its area on the unit sphere is 2π(1 − cos θc), and there are two such caps (top and bottom). Dividing by 4π gives the formula.

Reference numbers (single face)

  • PMMA → air: cos(42.1°) ≈ 0.741, so 74.1% trapped at one face.
  • GaN → air: cos(24.0°) ≈ 0.914, so 91.4% trapped at one face.
  • HRI → LRI (1.85/1.20): cos(40.4°) ≈ 0.762 — a higher guided fraction than HRI alone would trap against air (1.85 → air traps 87%, but the next stack layer up matters).