Agglomerates and measured haze

Why a nominally d-nm particle reads as 10×d when it clumps.

Lesson 5 of 5 · ~7 min read

A well-dispersed 50 nm particle is deep in Rayleigh at 550 nm. Let twenty of them clump into a 200 nm agglomerate and you are suddenly at x ≈ 1 — scattering jumps by orders of magnitude.

The (d/λ)⁴ hinge

Scattering scales as d⁴ in Rayleigh. A 10× increase in effective diameter is a 10⁴ increase in per-particle scatter. Dividing by the (fewer) number of agglomerated clumps still leaves a large net rise in haze.

How to see it

  • Haze vs wavelength. Rayleigh gives haze ∝ 1/λ⁴ (strong in blue, weak in red). Agglomerates flatten it; Mie-scale particles give a near-flat haze across the visible.
  • Haze vs film thickness. Dispersed particles give exponential loss in L. Settling or sedimentation gives a thickness-anomalous bottom-heavy haze profile.
  • DLS and TEM. Dynamic light scattering is the fastest check on effective hydrodynamic size; TEM is the ground truth. Discrepancies between DLS and the as-designed primary size are the usual tell.

What ISO 14782 is actually measuring

A haze meter integrates the forward scatter outside a ±2.5° cone. It is sensitive to the whole particle-size distribution through the Mie phase function; it is not a direct read of concentration. Two films with the same f can have very different ISO haze if their size distributions differ.