Practice test

Eight questions, instant feedback, unlimited retries. Score ≥ 7.0 / 10 to count the module as passed.

  1. Question 1

    In a glass / PVB / glass laminate without a cladding, what happens to edge-injected light?

  2. Question 2

    Guided fraction for a 1.52 glass plate laminated directly to PVB (n = 1.48), semi-infinite.

    • n_plate = 1.52
    • n_outside = 1.48
    • Return guided fraction (%)
    %
  3. Question 3

    How does a thin low-index cladding between glass and PVB restore edge-lit guiding?

  4. Question 4

    Guided fraction for a 1.52 glass plate with a 1.20 cladding, semi-infinite.

    • n_plate = 1.52
    • n_outside = 1.20
    • Return guided fraction (%)
    %
  5. Question 5

    If the cladding is too thin, what fails?

  6. Question 6

    Critical angle θ_c at a 1.52 glass / 1.20 cladding interface.

    • n_plate = 1.52
    • n_clad = 1.20
    • Return θ_c in degrees
    °
  7. Question 7

    Minimum cladding thickness so the per-bounce leak into PVB stays under 1 % at a 60° bounce angle. n_plate = 1.52, n_clad = 1.20, n_beyond = 1.48, λ = 550 nm.

    • n_plate = 1.52
    • n_clad = 1.20
    • n_beyond = 1.48
    • angle = 60°
    • λ = 550 nm
    nm
  8. Question 8

    When a halo around the logo has a blue cast, the usual root cause is