Practice test
Eight questions, instant feedback, unlimited retries. Score ≥ 7.0 / 10 to count the module as passed.
- Question 1
Why does the LRI Particle tool run Maxwell-Garnett in two stages instead of one combined bulk-average step?
- Question 2
Hollow silica (nshell = 1.46) in air: outer diameter 100 nm, shell thickness 10 nm. Enter the particle effective index.
- Outer diameter = 100 nm
- Shell thickness = 10 nm
- n_shell = 1.46
- n_core = 1.00
index - Question 3
A hollow sphere with a 5 nm shell has void fraction φvoid. Halving the shell to 2.5 nm (keeping outer diameter fixed) does what to φvoid?
- Question 4
Hollow silica (nshell = 1.46) in air: outer diameter 80 nm, shell thickness 5 nm. Enter the particle effective index.
- Outer diameter = 80 nm
- Shell thickness = 5 nm
- n_shell = 1.46
- n_core = 1.00
index - Question 5
In the two-stage MG, which argument acts as host in stage 2 — the binder or the particle?
- Question 6
Two-stage MG with 100 nm / 10 nm hollow silica in an organic binder (nbinder = 1.52). Volume fraction f = 0.50. Enter the effective coating index.
- Particle n (from previous step)
- Binder n = 1.52
- Volume fraction f = 0.50
- Max fraction = 0.74
index - Question 7
Same coating as p-6, then a third Bruggeman stage adds 30 % process porosity. Enter the final coating index.
- Starting coating n
- Process porosity p_proc = 0.30
- Air n = 1.00
- Mixing rule: Bruggeman
index - Question 8
For hollow-sphere particles the tool applies maxFraction = 1 at the particle-level MG, but keeps the usual 0.74 cap at the coating-level MG. Why?