The simulator reports a single-number uniformity score: 100 · min(grid) / max(grid) over a 128 × 80 grid sampled across the plate. 100 is perfect; 0 is pathological.
Where min and max usually sit
- max sits at the injection edge, in the corner nearest the brightest LED. Lambertian weighting plus local extraction density both peak there.
- min sits at the opposite corner — the ray path is longest and the local extraction density is tuned to work hardest, which still cannot fully compensate.
Why min / max, not mean / max
A mean / max metric is dominated by average brightness and misses the worst-pixel darkness that a viewer notices first. Visual uniformity is set by the darkest patch, not the average. The tool uses min / max for that reason, and samples on a coarse grid so a single-pixel outlier does not define the score.