Beleuchtung
LED luminaire
Industrial and hazardous-area light: optic and cover
In an LED luminaire the light passes a secondary optic and an outer cover, usually polycarbonate. Each bare surface reflects about 5 %, scratches and dirt scatter the beam, and in explosive atmospheres a plastic cover that charges up can discharge as a spark. A thin wet coating can carry hard coat, antistatic and anti-reflection on the same part.
Veröffentlichte Kriya-PositionPassgenaue Kriya-PositionWeitere Schicht
Vollständige Schichtliste (6)
- Antistatic hard coat, outer face Controlled surface resistance + scratch resistance (antistatic AR as an option)K1
- Cover or integral lens Polycarbonate · n 1.58 · often part of the enclosure
- Anti-reflection, inner face Protected sideK2
- Secondary optic TIR lens or lens array · PMMA or PC
- LED packages Phosphor-converted white LEDs · not Kriya
- Metal-core board and heat sink Not Kriya
Referenzen
- IEC 60079-0:2026 Explosive atmospheres — Part 0: Equipment — General requirements — clause 7.4: electrostatic charges on external non-metallic materials (contents preview)
- The non-metallic materials used in equipment for ATEX zones according to the IEC/EN 60079-0 standard — reducing the surface resistivity below 10⁹ Ω is one option against electrostatic charge
Zugehörige Kriya-Seiten
Hier verwendete Kriya-Werkzeuge
Schematisch, nicht maßstabsgetreu.