アンチグレア光沢 & DOI セレクター
How do anti-glare roughness and gloss relate for this surface?
60° 目標光沢を、予想されるヘイズ、クラリティ、DOIを伴うAGグレードにマッピングします。
How it works
An anti-glare surface scatters a fraction of incident light into angles away from the specular direction, lowering specular gloss and reducing mirror-sharp reflections. The scattered fraction scales with the surface roughness relative to the wavelength. The perceived image clarity trades off against the glare reduction.
Worked example
60° gloss 70 + DOI 85 → Kriya AG-7085
ASTM D523 + D5767 grid lookup.
Validation method, references and test-case results: /validation#ag-gloss-doi